8 OPTIONAL FUNCTIONS CCW-R-2**B INSTRUCTION MANUAL
8-20
8.3.5 Output During Count Set Production
During the count set weighing, output data display mode is changed from the weight display to the count
display as shown in the following.
Fig.8-19 Current Total Output (Example)
Table 8-8 Output Details
No. Name Remarks
1 Product code —
2 Product name —
3 Proper weight Number of times that the proper discharge is performed.
4 Target weight —
5 Total value Total discharged weight.
6 Mean value —
7 Standard deviation —
----------------------------
TOTAL DATA : 6
----------------------------
PRESET NUMBER: 6
DATE : 2006/AUG/16
START TIME 17:36
STOP TIME 17:42
--- C1 TOTAL ---
PROD CODE :
0002
PROD NAME :
CANDY
PROPER : 107
TARGET CNT: 50 pcs
TOTAL : 5386 pcs
MEAN : 50.3 pcs
STANDARD D: 0.548 pcs
MAX. : 55 pcs
MIN. : 50 pcs
RANGE : 5 pcs
PW MEAN : 5.00 g
STANDARD D: 0.00 g
PW MAX. : 5.07 g
PW MIN. : 4.91 g
----------------------------
78 0 0
77 0 0
76 0 0
75 0 0
74 0 0
73 0 0
72 0 0
71 0 0
70 0 0
69 0 0
68 0 0
67 0 0
66 0 0
65 0 0
64 0 0
63 0 0
62 0 0
61 0 0
60 0 0
59 0 0
58 0 0
57 0 0
56 0 0
55 0 0
54 0 0
53 0 0
52 0 0
51
28
50
49 0 0
48 0 0
47 0 0
NO OF *= 17
----------------------------
UNDER : 22
OVER : 9
OVER SCALE : 0
RECHECK CNT: 0
OVW DMP CNT: 0
OVS DMP CNT: 0
TOTAL : 0 kg
METAL DETECT: 0
ON TIME 0:02
OFF TIME 0:10
LOW TIME 0:00
( )
( )
1
2
3
4
5
6
7
8
9
10
11
12
13
14