6 FUNCTIONS OF THE OPERATION SCREENS CCW-R-2**B INSTRUCTION MANUAL
6-92
6.12.5 [Total Setting] Screen
Fig.6-90 [Total Setting] Screen ([Total Display] Screen)
Table 6-43 Items and Functions of [Total Setting] Screen
No. Name Function
1 [Every Combination Output] radio
button
Selects whether or not to output the combination weight in production.
[C1]/[C2]: Outputs the combination weight in production in the selected
channel.
[Off]: Does not output the combination weight in production.
2 [Operation Log Output] radio button Selects whether or not to output the operation log.
[On]: Outputs the operation log.
[Off]: Does not output the operation log.
3 [Operation Log Output Contents] Selects the contents to be logged, such as the log of commands executed by
the device and the errors that occurred during production.
4 [Action for Statistical Mem. Full]
radio button
Selects the action to be taken when the memory of total data is full.
[Stop]: Stops production.
[Continue]: Deletes old data and continues production.
5 [BATCH TOTAL INTERVAL]
increase/decrease key
Sets the total data printing interval in increments of 1 hour.
6 [Data Sampling Interval] increase/
decrease key
Sets the data sampling interval in increments of 1 minute.
7 [All Total] key Clears all total data up to the present.
Total data cannot be cleared during production.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA CCW-R-2 B Series and is the answer not in the manual?

ISHIDA CCW-R-2 B Series Specifications

General IconGeneral
BrandISHIDA
ModelCCW-R-2 B Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals