6 FUNCTIONS OF THE OPERATION SCREENS CCW-R-2**B INSTRUCTION MANUAL
6-78
6.11.6.3 Lower Weight Limit
The lower weight limit sets the lower limit of the proper weight for using average control.
When average control is used, the lower weight limit is automatically set by entering the target weight.
In the lower weight limit setting, the automatically set lower limit can be changed as required. However,
the range of change is from 0.0g to “the automatically set lower weight limit value”.
The maximum setting value and the minimum setting unit for lower weight limit are as shown below.
(e.g.) If the target weight is set to 100.0g and the upper and lower weight limit to 5.0g, discharge is
performed with the proper weight at 95.0g-105.0g.
Table 6-34 Lower Weight Limit Setting Range
Head Weighing Capacity Standard (400g/800g) Medium (800g/1600g)
Maximum setting value 999.0g 999.0g
Setting unit 0.1/0.2g 0.2/0.5g
Table 6-35 Automatically Set Lower Weight Limit Value
Target Weight (g) Automatically Set Value
5.0 - 50.0 9% of the target weight
50.0 - 100.0 4.5g
100.0 - 200.0 4.5% of the target weight
200.0 - 300.0 9g
300.0. - 500.0 3% of the target weight
500.0 - 1000.0 15g
1000.0 - 10000.0 1.5% of the target weight