11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES CCW-R-2**B INSTRUCTION MANUAL
11-14
11.2.5 Pattern 5
If an error occurs during operation or draining, warning alarm sounds and the weighing machine stops
automatically and the power is turned off automatically.
In addition, an error screen is displayed on the screen of the remote control unit.
Refer to “Table 11-6 Error Display List (Pattern 5)” for details on the error screen displayed in Pattern 5.
When a Pattern 5 error occurs, press the [Exit] key to exit the error screen and refer to “Table 11-6 Error
Display List (Pattern 5)” to perform the correcting action.
11.2.6 Pattern 6
If an error occurs during operation, warning alarm sounds and the weighing machine stops automatically.
In addition, an error screen is displayed on the screen of the remote control unit.
When a Pattern 6 error occurs, press the [Exit] key to exit the error screen and refer to “Table 11-7 Error
Display List (Pattern 6)” to perform the correcting action.
Table 11-6 Error Display List (Pattern 5)
Error Name/
Error Description
Cause Action
[AFV ZERO ERROR] 1. When performing manual zero
adjustment or auto zero adjustment of
AFV cell, zero cannot be obtained.
1. Perform manual zero adjustment.
[AFV PARAMETER
ERROR]
1. Improper weighing data. 1. Check the weigher specification setting.
[AFV COMPENSATION
ERROR]
1. AFV compensation is not operating
properly.
1. Contact the distributor or Ishida customer
support to request repair service.
[AFV OUTPUT ERROR] 1. Poor connection of the connector.
2. Contact with the spacers.
3. Improper sensitivity of the AFV cell.
1. Contact the distributor or Ishida customer
support to request repair service.
[AFV OVERFLOW ERROR] 1. Poor connection of the connector.
2. Contact with the spacers.
3. Improper sensitivity of the AFV cell.
1. Contact the distributor or Ishida customer
support to request repair service.
Table 11-7 Error Display List (Pattern 6)
Error Name/
Error Description
Cause Action
[Total Overflow!] 1. There is not enough memory for total
data backup.
1. Clear all of the totals or change the “Action for
Statistical Mem. Ful” from “Stop” to
“Continue” in order to continue the operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA CCW-R-2 B Series and is the answer not in the manual?

ISHIDA CCW-R-2 B Series Specifications

General IconGeneral
BrandISHIDA
ModelCCW-R-2 B Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals