CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-77
6.11.6.1 Target Weight
The target weight sets the weight of products to be discharged from the device to the packer.
The maximum setting value and the setting unit for target weight are as shown below.
6.11.6.2 Upper Weight Limit
The upper weight limit sets the upper limit of the proper weight.
The upper weight limit can be set within the range of 0.0g-999.0g. If 0.0g is set, the upper weight limit
is infinite.
The maximum setting value and the minimum setting unit for upper weight limit are as shown below.
(e.g.) If the target weight is set to 100.0g and the upper weight limit to 5.0g, discharge is performed with
the proper weight at 100.0g-105.0g.
Table 6-32 Target Weight Setting Range
Head Weighing Capacity Standard (400g/800g) Medium (800g/1600g)
Maximum setting value 99999.0g 99999.0g
Setting unit 0.1/0.2g 0.2/0.5g
Table 6-33 Upper Weight Limit Setting Range
Head Weighing Capacity Standard (400g/800g) Medium (800g/1600g)
Maximum setting value 999.0g 999.0g
Setting unit 0.1/0.2g 0.2/0.5g