9 CLEANUP PROCEDURES CCW-R-2**B INSTRUCTION MANUAL
9-18
9.4.2.2 Remote Control Unit
Do not rub hard or use adhesive tape to remove dirt when cleaning the
operation screen.
Do not clean the operation screen with organic solvents such as thinner or
benzin.
Do not pour detergent directly over the operation screen.
Table 9-11 Washing and Sterilization Methods of Main Body, Dispersion Portion, and Drive Portion
(WP Specification)
Washing method Brushing wash or wipe wash. (Neutral detergent)
Sterilization
method
Spray sterilization or wipe sterilization.
Alcohol: 80
v
/
v
%.
Or,
sodium hypochlorite (available chlorine concentration 250 ppm).
Table 9-12 Washing and Sterilization Methods of Main Body, Dispersion Portion, and Drive Portion
(PB, SS Specification)
Washing method Wipe wash. (Neutral detergent)
Sterilization
method
Wipe sterilization.
Alcohol: 80
v
/
v
%.
1. After washing and sterilizing, wipe with a
damp cloth in water and dry. (For the washing
and sterilization methods, refer to “Table 9-13
Washing and Sterilization Methods of Remote
Control Unit”)
Fig.9-18 Remote Control Unit Cleaning
Table 9-13 Washing and Sterilization Methods of Remote Control Unit
Washing method Wipe wash. (Neutral detergent)
Sterilization
method
Wipe sterilization.
Alcohol: 80
v
/
v
%.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA CCW-R-2 B Series and is the answer not in the manual?

ISHIDA CCW-R-2 B Series Specifications

General IconGeneral
BrandISHIDA
ModelCCW-R-2 B Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals