10 MAINTENANCE AND INSPECTION CCW-R-2**B INSTRUCTION MANUAL
10-2
10.2 Daily Inspection
This section describes the daily inspection items.
10.2.1 Pre-start Inspection
Perform the following pre-start inspection before production.
• If any part of the weighing machine is not securely installed, it may fall due to
vibration during the production and may damage the weighing machine or
injure personnel.
• The installation methods for each part are explained in “12.4 Installation Procedure”.
Table 10-1 Pre-start Inspection List
Inspection Item Inspection detail
Weighing machine and vicinity of
weighing machine
Make sure that tools and any other irrelevant objects are not placed on top of or in
the vicinity of the weighing machine.
Installing dispersion table Make sure that the dispersion table is securely installed with no play.
Interference between dispersion table and
radial trough
Make sure that the dispersion table does not make contact with the radial troughs.
( 10.2.1.1 Dispersion table)
Interference between radial troughs Make sure the radial troughs are not touching each other.
( 10.2.1.2 Radial trough)
Installing hoppers Make sure that the roller of each hopper securely fits into the U-shape groove of
the switching lever.
Installing collection chute Make sure that the collection chute is securely installed.
Installing timing hopper Make sure that the timing hopper and the drive unit are securely connected with
the drive lever.
Confirming the dew-point checker of the
air dryer(WP specification)
Confirm performance of the air dryer by checking the grain color of the dew point
checker.
( 10.2.1.3 Confirming the dew-point checker of the air dryer (WP
specification)