CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-157
4 [Interface] drop-down key Selects the interface for interlocking this device and the packer from [Slave],
[Master], [Stroke On Demand] and [Bag On Demand].
5 [Manual Dump Initiate] radio button Selects the operation of discharge based on the manual interlock signal, from
[Self] or [Sync].
[Self]: Performs discharge automatically without input of the interlock signal.
[Sync]: Performs discharge based on the interlock signal from the packer.
6 [Manual Dmp Confirm] radio button Selects whether or not to output the discharge completion signal during drain,
zero adjustment and error discharge.
[Off]: Does not output the discharge completion signal during drain, zero
adjustment and error discharge.
[On]: Outputs the discharge completion signal during drain, zero adjustment
and error discharge.
Table 6-75 Items and Functions of the [Pckr Intrlck Set] Index Screen (Continued)
No. Name Function