CCW-R-2**B INSTRUCTION MANUAL 8 OPTIONAL FUNCTIONS
8-15
Each piece weight revision range in this example is shown in “Table 8-6 Piece Weight Revision Range
List”.
When the value for the piece weight revision is set to 1/1, the piece weight revision range is more
restricted, but more products supplied into each hopper can be identified (maximum target count value).
When set to 1/4, the piece weight revision range broadens, but the amount of products supplied into each
hopper and identified by the device is more restricted.
Table 8-6 Piece Weight Revision Range List
Setting Value for
Piece Weight
Revision
Piece Weight Revision Range
(Target count: 20, piece weight: 5g)
Recognition
Range
1/1 4.875g < Piece weight revision range < 5.125g 1 to 20
1/2 4.75g < Piece weight revision range < 5.25g 1 to 10
1/4 4.5g < Piece weight revision range < 5.5g 1 to 5