CCW-R-2**B INSTRUCTION MANUAL 9 CLEANUP PROCEDURES
9-3
• Use a neutral detergent for washing. Choose a detergent that does not affect
silicon materials.
3. To dry after washing, wipe the surface with a soft cloth.
4. To prevent product residue from adhering, wash and dry the components daily.
• Avoid overload to the weigh drive unit and dispersion feeder. These
components are interlocked to the weight sensor.
• For cleaning of the rubber cover installed on the feeder cover, do not use tools
such as a brush or any tools with sharp parts.
Washing and drying methods in the vicinity of the weigh drive unit
The previous section described the washing and drying methods for the unremovable units. As for the
weigh drive unit, especially because precision parts are installed around the unit, wash and dry following
the precautions below, in addition to the washing and drying methods for components.
Fig.9-2 Washing of Weigh Drive Unit
Maintain a hose angle of approximately 45° during washing, and keep a distance of 50 cm or more from
the components.
over 50 cm
The part directly
connected to the
weigh sensor
Diaphragm
Expansion figure of Weigh Drive Unit