CCW-R-2**B INSTRUCTION MANUAL 11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES
11-9
[NETWORK ERROR]
/DUC NODE SETTING
ERROR
1. Error has occurred in the
communication network.
This error occurs when the
CPU or board is damaged.
1. Contact the distributor or Ishida customer
support to request repair service.
[RECHECK ERROR] 1. The result of the combination by count
is not within “target weight - lower
weight limit” and “target weight +
upper weight limit”.
This error occurs when the
count set weighing
(optional) is used.
1. Check the set value of the upper and lower
weight limits.
[FDRV ERROR] 1. Error has occurred in the
communication network.
This error occurs when
there is a failure in the
communication line.
1. Contact the distributor or Ishida customer
support.
Table 11-3 Error Display List (Pattern 2) (Continued)
Error Name/
Error Description
Cause Action

Table of Contents