386 Matrix ETERNITY NE System Manual
With this configuration, ETERNITY will calculate the call cost as follows:
An Outgoing Call is made by an extension user, to the number ‘2630555’ through the trunk, CO-1 at
20:10 hours. The ETERNITY will check the Call Cost Calculation parameters singed on the trunk
and determine the Time Zone as per time of the call.The system will also check the corresponding
Pulse Rate Option configured on the trunk.
In this example, Time Zone for CO-1 at 20:10 Hours would be Time Zone 1, and the Pulse Rate
Option for CO-1 is ‘1’.
The ETERNITY will match the dialed number ‘2630555’ in the Area Code table. A best match is
found with the entry configured at index 001 in the Area Code Table.
As per the Area Code Table, the Pulse Rate Type ‘03’ is programmed in ‘Pulse Rate Option 1’ for
the matching entry (at Index 001).
(However, if CO-1 would have been assigned Pulse Rate Option ‘2’, the Pulse Rate type ‘06’ would
have been selected as shown in Area Code Table)
Finally, for Pulse Rate Type ‘03’, ETERNITY will consider the Cost for the First Unit as 1.00 (As. or
$as per applicable currency) for the duration of 30 seconds and for the additional unit also, the cost
will be considered as 1.00 for the duration of 30 seconds. (See Pulse Rate Table). This data will be
used for calculating the total cost of call based on the total duration of the call.
How to configure
To be able to use Call Cost Calculation, you must do the following:
Define the Unit and Service Charge on the basis of which call cost is to be calculated.
Assign Call Cost Calculation Pulse Rate Option and the Call Cost Calculation Schedule on the trunks on
which you want to apply this feature.
Configure the Pulse Rate Types for the Pulse Rate Option you assign to the trunk.
You may configure different Pulse Rate Types of Normal Days and for Holidays, as required. If configuring
Holiday Pulse Rate, you must also configure the Holiday schedule.
05
Duration (sec) 180 180 180 180 180 180 180 180
Cost 03.00 03.00 03.00 03.00 03.00 03.00 03.00 03.00
:
Durations) ::::::::
Cost ::::::::
32
Duration (sec)
Cost
Pulse Rate Type
Time Zone T1 Time Zone T2 Time Zone T3 Time Zone T4
First
Unit
Add.
Unit
First
Unit
Add.
Unit
First
Unit
Add.
Unit
First
Unit
Add.
Unit

Table of Contents