478 Matrix ETERNITY NE System Manual
With the necessary configuration done at both locations, when an extension user 201 of ETERNITY at
Location A dials extension 301 of PBX A, the system checks the CUG table to match the dialed digits with
the Route Code and the Dialed Digit Count. As a match is found, it selects the Tie Trunk defined for routing
the Route Code, i.e. CO1.
If the CUG is connected over IP network, you must also configure the SIP Trunk as Peer-to-Peer trunk
and configure the Peer-to-Peer Table. See “Peer-to-Peer Calling” for instructions.
How to configure
To configure Closed User Group,
Open Jeeves.
Log in as System Engineer.
Click the Advanced Settings link.
Click the Closed User Group link. The Closed User Group Table page opens.
•In the Route Code field, enter the extension numbers of the other PBX in the CUG. Instead of entire
number strings, you can configure a single digit, the starting digit of the extension numbers as Route Code.
A maximum of 16 digits can be configured as Route Code. Default: Blank.
Keep the Strip Digit Count as ‘0’. Default: 0
Keep the Self Route flag disabled. Default: Disabled.
Keep the LCR flag disabled. Default: Disabled.