790 Matrix ETERNITY NE System Manual
• Property Code: This is the property code required by the CAS used in the organization. It is a string of
alphanumeric characters and is to be terminated with #*. This field has a maximum of 128
alphanumeric characters.
You must program this string keeping in mind the field length used by the selected/customized posting
protocol.
The default value of the default Property Code String has been set as 'AAA', as at least two known
protocols use this field. You can set a different value here and the new value will appear in the CDR
record, irrespective of the protocol type selected.
If Bell Hobic or Hilton has been selected, you should program this field as 'AAA'. If Xiox protocol has been
selected, you should program this field as HTL. These values are not protocol dependent, but can be
configured by you.
• Extension Number: This is the extension number from which the call was made. You can define the
column position and the field length of the Extension number in the Call Detail Record.
• Trunk Number: This is the number of the trunk from which the call was made.
The Matrix Format occupies 5 character spaces.
Check-Inn Format occupies 4 character spaces.
The First Character in the Check-Inn Format is X (Fixed). The remaining three characters show the
software port number.
• Date: The date on which the call was made. The date fill flag is to be enabled.
• Filler Character field is applicable for Date, Month and Year, i.e. whether the single digit date is to be
printed as space-X or 0-X. For example, date = 1 is to be displayed as '1' or '01'.
• Where leading zeroes are not required, the date, month and year sub-fields are right aligned and the
spaces are filled with character 'space'.
• The Date field is not linked to the global flag of Date Format. The global Flag of Date format is used,
while using features or in configuration reports but not in CAS. This is because the date format used by
the CAS is not the same as used by the users of the system.
• Time: The time when the call was made. The format of the time field and the time fill flag are to be
programmed.
• Filler Character field is applicable for Hours, Minutes and Seconds i.e. whether the single digit hour is
to be printed as space-X or 0-X. For example, hour = 1 is to be displayed as '1' or '01'.
• In case leading zeroes are not required, Date, Month and Year sub-fields are right aligned and the
spaces are filled with character 'space'.
• Duration: The duration of each call. Program the duration unit and the duration fill flag.
When Duration Unit = Minutes, the rounding off to the nearest whole number is done. For seconds <= 30,
Minute is not incremented. For seconds > 30, minute is incremented.