CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-67
3 [Average Control] radio button Selects whether or not to perform average control.
This controls the target weight at a regular interval in order to maintain the
discharged weight mean value to be close to the target weight.
If this button is set to [On] in mix weighing, the lower limit value set for the
section is used as the lower limit for the target weight of the mixed products.
If [Off] is selected, products of a weight lower than the target weight are
controlled so as not to be dumped.
4 [Interlock Parameter Number] drop-
down key
Selects the packer interlock method.
( Table 6-25 Packer Interlock Setting (Example))
5 [Section Parameter Number] key Selects the section parameter number from the list.
This selects the section division pattern when dividing weigh heads into
sections and weighing different products in each section.
There are eight different division patterns (1-8).
The section division patterns are set at the [Installation] level in advance.
Table 6-24 Optimum Dump Count
Range Optimum Dump Count (Fractions rounded up)
400/800
Set target
÷ 2277.7
800/1600
Set target ÷ 5461.2
1000/2000
Set target ÷ 7192.7
2000/4000
Set target
÷ 15384.5
Table 6-25 Packer Interlock Setting (Example)
Parameter No. Mode Description
1 [Master]
( 2.5 Term Description)
2[Slave]
3 [Stroke On Demand]
4 [Bag On Demand]
Table 6-23 Items and Functions of [Machine] Tab Screen (Continued)