6 FUNCTIONS OF THE OPERATION SCREENS CCW-R-2**B INSTRUCTION MANUAL
6-100
• When less than 4 heads are selected, the settings will influence the weighing accuracy. Set both of the feeder
amplitude and operation time to values about 5 points lower than normal and wait for 1-2 minutes to check the
condition.
• When feeder control is automatic, the feeder amplitude and feeder operation time settings are
used only temporarily and automatic control will be prioritized as time passes.