CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-107
3. [Auto Multi Control], [Auto Time Multi Control], [Auto AMP Multi Control]
Controls each RF independently, as with 2. [Efficiency Ref. Control]. These modes can be selected
when automatic and detailed control is desired when infeed and dispersion to each radial feeder are
stable.
Especially when the feeder amplitude needs to be fixed to a certain value in cases that products
cannot move unless high feeder amplitude is set, select [Auto Time Multi Control]. When the feeder
time needs to be fixed during high-speed production or other cases, select [Auto AMP Multi
Control].
As an instruction for use, adjust layer thickness on the dispersion feeder by adjusting DF weight or
inlet chute height to adjust only the amount of product infeed from the dispersion feeder to the radial
feeder, as these modes do not control RF/DF amplitude and time independently. When infeed or
dispersion to each radial feeder is unstable or tends to be uneven, the efficiency may be lowered. In
this case, select other mode.
4. [Auto Single Control], [Auto Time Single Control], [Auto AMP Single Control]
Unlike other auto control modes, these modes control the whole RF. When 2. [Efficiency Ref.
Control] or 3. [Auto Multi Control] is selected, extremely uneven infeed may occur or frequent
empty head may occur at a specific head. In such cases, selecting these modes will enable response
only to overall status changes generated over a long time due to such causes as influence by deposits.
As with 3. [Auto Multi Control], select Auto AMP Single Control when the feeder time needs to be
fixed to a certain value during high-speed production or other cases, and select [Auto Time Single
Control] when the feeder amplitude needs to be fixed in cases that products cannot move unless high
feeder amplitude is set.
As an instruction for use, set the RF amplitude and RF time balance between heads manually in
consideration of infeed variance, etc. As with 3. [Auto Multi Control], adjust the amount of product
infeed on the dispersion feeder by adjusting DF weight or inlet chute height to adjust only the amount
of product infeed from the dispersion feeder to the radial feeder, as these modes do not control RF/
DF amplitude and time independently.