6 FUNCTIONS OF THE OPERATION SCREENS CCW-R-2**B INSTRUCTION MANUAL
6-118
3. Press the [WH Span Adjustment] key .
X The span adjustment starts.
Fig.6-119 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)
4. Make sure that the weight display of the
selected head is 200.0±0.1g.
• Make sure that the weight display of the
selected head is 200.0±0.1g. If the
weight display reading exceeds 200.1g
or falls below 199.9g, repeat the
procedure from step 2.
Fig.6-120 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)
5. Remove the span adjustment weight from the
weigh hopper.
X Make sure that the weight display of the
selected head is in the proximity of 0.0±0.1g.
• If the weight display of the selected
head exceeds 0.1g or falls below -0.1g,
repeat the procedure from step 2 in
“4.4.8 Zero Adjustment”.
Fig.6-121 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)