CCW-R-2**B INSTRUCTION MANUAL 6 FUNCTIONS OF THE OPERATION SCREENS
6-117
About zero adjustment
Zero adjustment is performed while the [Power] key is on.
Zero adjustment is performed for the weigh head displayed in blue.
Zero adjustment cannot be executed for the weigh unit and dispersion unit simultaneously.
When [Multi Dump Initiate] in [Pckr Intrlck Set] is set to [Sync], zero adjustment does not
operate without interlock signal from the packer. In this case, interlock the device with the
packer.
Before starting zero adjustment for the weigh unit, products in the weigh hopper are
automatically discharged.
In addition, check the span. (See the following.)
Span adjustment procedure
1. Place the span adjustment weight on the weigh
hopper for which span is to be adjusted.
Normally the span adjustment weight is
200g. However, it may vary depending
on the specifications.
Fig.6-117 Weigh Hopper
2. Select the head to be adjusted.
X The selected heads are displayed in blue.
To adjust all heads, press the [All Head
SLCT/CLR] key .
Fig.6-118 [Weighing Adjst] Tab Screen
([Manual Adjustment] Screen)
SPAN
ADJUSTMENT
WEIGHT

Table of Contents