11 CAUSES AND ACTIONS FOR ERRORS AND FAILURES CCW-R-2**B INSTRUCTION MANUAL
11-12
**ERROR
/POWER ERROR
There is no power supplied to
the motor.
(**: PH, WH, and BH)
1. The fuse in the main body is blown.
• This error occurs when the
power is not supplied to the
drive unit.
1. Replace the fuse.
**ERROR
/DRIVE PATTERN CALC
ERROR
(**: PH, WH, and BH)
1. Setting of the hopper action parameter
is improper.
1. Initialize the setting of the drive specification.
**ERROR
/DRIVE PARAMETER
NON-RECEPTION ERROR
(**: PH, WH, and BH)
1. Communication is interfered due to
momentary power loss of the power
supply. (A failure in the communication
line inside the weigher.)
2. The drive unit was requested to drive
before receiving the drive parameters
from the remote control unit.
1. Turn off the main power switch and turn it on
again.
**ERROR
/CYCLE OVERLAP ERROR
(**: TH, DTH, and RS)
1. Hopper opening and closing are
overlapped.
• This error occurs when
attempting to operate the
running drive unit of TH,
DTH or RS in the next
cycle.
1. The setting of the weigher speed is too high.
Lower the weigher speed.
Table 11-4 Error Display List (Pattern 3) (Continued)
Error Name/
Error Description
Cause Action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ISHIDA CCW-R-2 B Series and is the answer not in the manual?

ISHIDA CCW-R-2 B Series Specifications

General IconGeneral
BrandISHIDA
ModelCCW-R-2 B Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals