CCW-R-2**
ï¼¢
INSTRUCTION MANUAL 4 OPERATION PROCEDURES
4-17
Next, perform the zero adjustment operation for the dispersion table.
X When zero adjustment operation finishes,
each [WH] key displays the respective
weight.
3. Make sure that each weight display of the [WH]
key is within 0.0±0.1g.
• If the weight display reading exceeds
0.1g or falls below -0.1g, perform the
zero adjustment again.
• Zero adjustment may not be performed
accurately within 30 minutes after
turning the power on or when there is
air movement around the machine.
• Pressing each [Weigh Hopper] key on
the screen can switch the hopper status
to selected or unselected.
Fig.4-31 [Zero Adjustment] Screen