Epson Stylus Pro 4900/Epson Stylus Pro 4910 Revision A
ADJUSTMENT Head Related Checks and Adjustments 348
Confidential
14. Make sure that the date and time printed in the second line on the upper left of the
chart (measurable time and date) is within the range displayed under the heading
“GMT” on the lower screen. (If the date and time is not within the range, it is
necessary to print the chart again.)
15. Refer to Figure 4-56, lay the chart on the black paper (or sheet) with the upper part
of the chart facing left side, and set the scanning ruler onto the bottom most patch
line.
Figure 4-55. Measurable Time and Date Check
Figure 4-56. Setting the Chart and the Scanning Ruler
2010-08-29 09:35 (GMT 2005-08-29 00:35)
2010-09-05 09:30 (GMT 2005-09-05 00:30)
S/N : 0000000000 OS : Win BlackInk:Matte
Printer : Epson Stylus Pro XXXXX
Version : XXXXXXXXXX
C VM MB GY OR GR LGY Y LVM LC
Nozzle check
pattern
Calibration
patch
2010-08-29 09:35 (GMT 2005-08-29 00:35)
2010-09-05 09:30 (GMT 2005-09-05 00:30)
S/N : 0000000000 OS : Win BlackInk:Matte
Printer : Epson Stylus Pro XXXXX
Printed date and time
Main unit serial
number
Measurable date and time
Product name
OS type Black ink type
Set the scanning ruler with its guide gap matched with the patch.