ADJUSTMENT Head Related Checks and Adjustments 345
Confidential
6. Load an A4-sized paper vertically on the paper tray, click [Next] to start the nozzle
check.
7. Check the nozzle pattern. If there is any defect, execute the cleaning using the
Control Panel of the printer.
If the check pattern is appropriate, click [Next].
8. Load an A4-sized Archival Matte Paper vertically on the paper tray, and click
[Next] to print the calibration chart.
Figure 4-52. Entire Process Screen
C A U T I O N
Make sure to confirm that there is no dot missing for all nozzles
before executing Colorimetric Calibration Adjustment.
C A U T I O N
Make sure to leave the adjustment chart for 5 minutes to dry it out.
Wait for the countdown to end.