84
────────────────────────────────────────────────────
6.2 Operation Sequence (RMS)
────────────────────────────────────────────────────
See Chapter 2
Settings on the STATUS screen
Press the
STATUS
key to display
the STATUS screen.
Preparation
Basic Settings
Function
Select the RMS recorder function.
Time axis range
Determine the speed with which the
input signal waveform is captured.
Frequency
Select 50 Hz or 60 Hz.
Recording length
Determine the length of the data
sample for a single measurement.
Display format
Select the format type for the
waveform display screen.
Print mode
Select the waveform or numerical
value to be output the measured data
Set the print interval (numerical
format)
Additional recording
Set whether additional recording is
required.
Print function
Select whether or not to print out
simultaneously with screen display.
Auto save function
Select whether or not to save the
waveform automatically
See
Section 6.3
Installation of the Unit
Turn on the power
Connect the inputs
6.2 Operation Sequence (RMS)
(12) Additional recording function
The first set of measurement data is preserved, and recording of the second
set of measurement data starts after the first set.
(13) Logging function
Numeric printout of waveform data
(14) Reprint function
The most recent 2000 (32 M words: 10000) divisions of the data stored in
memory can be printed as many times as required.
(15) Print
Real-time print, manual print, partial print, report print, screen hard copy can
be printed.