EasyManuals Logo

Tektronix Keithley SourceMeter 2470 Reference Manual

Tektronix Keithley SourceMeter 2470
995 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
2470
High Voltage SourceMeter Instrument Reference Manual Section 3:
Instrument description
2470-901-01 Rev. A / May 2019 3-49
If an autoexec script already exists, you must delete it by sending the
script.delete("autoexec")
command. Performing a system reset does not delete t
he
autoexec
script.
Resets
There are several types of resets in the 2470.
In general, the terms "reset," "instrument reset," and "system reset" refer to the reset that is
performed when you send the *RST or reset() command, or when you select MENU > System >
Info/Manage > System Reset from the front panel. It resets most commands to their default values.
For more information about the settings that get reset, refer to Reset default values (on page 5-28
).
The instrument also responds to other types of resets. These resets include:
• SMU reset: This reset is only available if you are using the TSP command set. The smu.reset()
function turns off the output and resets any commands that begin with smu. to their default
values. Refer to smu.reset() (on page 14-150
).
• Password reset: This resets the instrument password to its default value. You can reset the
pas
sword by pressing the MENU key, selecting Info/Manage (under System), and selectin
g
P
assword Reset. When you do this, the password returns to the default setting. Refer t
o
Instrument access (on page 2-37
).
• Digital line reset: This resets digital I/O line values to their factory defaults if you are using the
T
SP command set. If you are using SCPI, the lines are reset when the system is reset.
• LAN reset: This resets the LAN settings and the instrument password to the system default
values. To do this reset, insert a straightened paper clip into hole below LAN RESET on the rear
panel. For the location of LAN RESET, refer to Rear panel overview (on page 3-3
).
• Status preset: This resets all bits in the status model. If you are using the SCPI command set,
refer to :STATus:PRESet (on page 12-100
). If you are using the TSP command set, refer to
status.preset() (on page 14-184).
• Trigger blender reset: This reset is only available if you are using the TSP command set.
Resets some of the trigger blender settings to their factory defaults. Refer t
o
tr
igger.blender[N].reset() (on page 14-194
).
• Trigger timer reset: This reset is only available if you are using the TSP command set. Resets
trigger timer settings to their default values. Refer to trigger.timer[N].reset() (on page 14-256
).
• TSP-Link line reset: This reset is only applicable if you are using TSP-Link. Resets some of the
T
SP-Link trigger attributes to their defaults. Refer to tsplink.line[N].reset() (on page 14-272
).
• TSP-Net reset: This reset is only applicable if you are using TSP-NET. Disconnects all TSP-Net
sessions. Refer to tspnet.reset() (on page 14-283
).

Table of Contents

Other manuals for Tektronix Keithley SourceMeter 2470

Questions and Answers: