In this section:
Introduction to reading buffers .................................................. 6-1
Getting started with buffers ...................................................... 6-2
Creating buffers ........................................................................ 6-5
Setting reading buffer options .................................................. 6-9
Selecting a buffer ................................................................... 6-14
Using the front panel to store readings in the selected buffer 6-17
Viewing and saving buffer content ......................................... 6-18
Clearing buffers ...................................................................... 6-24
Deleting buffers ...................................................................... 6-25
Remote buffer operation ........................................................ 6-25
Introduction to reading buffers
Reading buffers capture measurements, ranges, the output state of the instrument, and instrument
status. The 2470 has two default reading buffers. You can also create user-defined reading buffers.
Reading buffers provide statistics, including average, minimum, maximum, and standard deviation. If
you use SCPI commands over the remote interface, peak-to-peak statistics are also available.
When you create a reading buffer, that buffer becomes the active buffer until you choose a different
buffer.
You can perform the following operations on reading buffers from the front panel or a remote
interface:
• Configure, store, and recall reading buffers.
• View reading buffer content.
• Choose to store readings in a default reading buffer or the user-defined reading buffers.
• Save reading buffer content to a USB flash drive.
• Set reading buffers to fill once or fill continuously.
• Change the capacity of reading buffers.
• Delete user-defined reading buffers. You cannot delete defbuffer1 and defbuffer2.
• Clear reading buffers.
• Clear the default reading buffers and delete the user-defined reading buffers by turning the
instrument off or sending an instrument reset command.
Section 6
Reading buffers

Table of Contents

Other manuals for Tektronix Keithley SourceMeter 2470

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix Keithley SourceMeter 2470 and is the answer not in the manual?

Tektronix Keithley SourceMeter 2470 Specifications

General IconGeneral
BrandTektronix
ModelKeithley SourceMeter 2470
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals