Maintenance Object Repair Procedures
555-233-123
10-736 Issue 4 May 2002
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 FAIL Emergency Transfer is manually turned OFF via the
Emergency Transfer switch(es).
2 FAIL Emergency Transfer is manually turned ON via the Emergency
Transfer switch(es).
1. Place the switch (or switches in a PPN for a High or
Critical Reliability system) in the AUTO position.
PASS The system software has control of Emergency Transfer within
this port network. If Emergency Transfer is invoked, then there
can be a Major alarm in the system that is invoking Emergency
Transfer. The following table lists the error types and MOs that
may cause Emergency Transfer. If any or all of these errors
appear in the log, then refer to the appropriate Maintenance
documentation and resolve those problems first.
If none of these errors appear in the log, then check the
Emergency Transfer hardware. Specifically, on the EPN, if
Emergency Transfer is invoked while call processing is
permitted, verify that the current limiter card (982LS) is in the
correct slot on the backplane. If the current limiter card is not in
the correct slot, move it to the correct location and rerun this
test.
Table 10-276. Test #124 Error Log Entries That Cause Emergency Transfer
MO Name Error Type Aux Data
SW-CTL 1
SW-CTL 2
TONE-BD 1 0
TONE-BD 2305 0
Continued on next page
Table 10-275. TEST #124 Emergency Transfer Query Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page