EasyManua.ls Logo

Avaya Definity SI - ADX8 D-BD (AUDIX Circuit Pack)

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADX8D-BD (AUDIX Circuit Pack)
Issue 4 May 2002
10-15 555-233-123
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in digital-port
(DP) mode. For circuit pack problems, see XXX-BD (Common Port Circuit
Pack). Port level problems are covered by ADX8D-PT.
EMBEDDED AUDIX
consists of two circuit packs that occupy 5 slots on a port
cabinet. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log) Alarm Level Initial Command To Run
1
1 UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX8D-BD MINOR or
WARNINGS
test board PCSS sh AUDIX Circuit Pack