ADX8D-BD (AUDIX Circuit Pack)
Issue 4 May 2002
10-15 555-233-123
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 EMBEDDED
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in digital-port
(DP) mode. For circuit pack problems, see “XXX-BD (Common Port Circuit
Pack)”. Port level problems are covered by ADX8D-PT.
EMBEDDED AUDIX
consists of two circuit packs that occupy 5 slots on a port
cabinet. The tests described in this manual apply only to switch-side maintenance
which tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
MO Name (in
Alarm Log) Alarm Level Initial Command To Run
1
1 UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21).
Full Name of MO
ADX8D-BD MINOR or
WARNINGS
test board PCSS sh AUDIX Circuit Pack