status access-endpoint
Issue 4 May 2002
8-299555-233-123
status access-endpoint
This command displays diagnoses internal software and helps to locate facilities
with which Access Endpoints communicate.
spe-standby The default option for a High or Critical Reliability System. If a
restart occurs on active SPEs and the corresponding vector bit is
set, a core dump occurs on the standby SPE (after the standby
SPE has performed a memory refresh).
spe-active Option for a High or Critical Reliability System; default for simplex
SPE systems. If a restart occurs on active SPEs and the
corresponding vector bit is set, core dumps occur on the active
SPE. This option disrupts service.
spe-maint Available for High or Critical Reliability Systems. If restarts occur
on active SPEs and the corresponding vector bit is set, core
dumps occur on standby SPEs without the standby SPE a
memory refresh.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
status
access-
endpoint
extension
print
extension number of the access endpoint
prints reports to SAT printers.
Examples:
status access-endpoint 25012
status access-endpoint 77868
status access-endpoint 66078 print
init
inads
craft
cust
nms
browse
none none