EasyManua.ls Logo

Avaya Definity SI - Test Trunk

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
test trunk
Issue 4 May 2002
8-493555-233-123
test trunk
This command performs hardware diagnostic tests on an entire trunk group or an
individual trunk group member, depending on the options entered.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
trunk
group
number
member
number
short
long
repeat
number
clear
schedule
Administered group number (1-99)
Administered number identifying a particular
trunk within a trunk group (1-99).
Command executes a series of
nondestructive diagnostic tests.
Command executes a more comprehensive
and longer version of the both destructive
and nondestructive diagnostic tests.
How many times each test in the sequence is
repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence fails.
1
Command is validated and then a scheduling
form displays to schedule execution of the
command. The command is then placed in
the command queue and is executed at the
specified time. The information displayed by
the command is sent to the system printer
instead of the screen.
2
Examples:
test trunk 78 l
test trunk 80/1 sh r 2
test trunk 78/2 l r 25
test trunk 78/2 l r 25 schedule
test trunk 80
test trunk 80 schedule
test trunk 78 r 4
test trunk 78 c
1 If no alarms are registered against the maintenance object then the test sequence exercises once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
Test Seq. =
short;
Repeat = 1
none

Table of Contents