EXT-DEV ADMIN? N (External Device Alarm)
Issue 4 May 2002
10-817555-233-123
EXT-DEV ADMIN? N (External Device
Alarm)
NOTE:
Use this Maintenance Object when the External Device Alarm Admin? field
on the System-parameters Customer-options form is set to (n).
In the Standard Reliability PPN the Maintenance Processor (TN786B or
TN2404/TN790) in carrier (A) monitors the EXT-DEV alarm leads. In the High or
Critical PPN, the Duplication Interface (TN772) circuit pack in carrier (A) monitors
the EXT-DEV alarm leads, and provides status to the Maintenance processor
(TN786B or TN2404/TN790) in the active SPE. In the EPN the Maintenance
Board (TN775) monitors the EXT-DEV alarm leads. The system only recognizes
pairs connected to the 1M and 1m (ALARM MONITOR) leads. Pairs connected to
the 2M, 2m, 3M, 3m, and 3w are not recognized by the system.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run
1
1 Where UU is an appropriate cabinet number determined via the PORT field from the
Alarm or Error Log.
Full Name of MO
EXT-DEV MAJOR test environment UU External Device Alarm
EXT-DEV MINOR test environment UU External Device Alarm