EasyManua.ls Logo

Avaya Definity SI - Busyout Packet-Control

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-12 Issue 4 May 2002
Field descriptions
busyout packet-control
This command places the packet-control circuit pack in a maintenance busy state,
and tears down each point-to-point signaling link that terminates on this
packet-control. No periodic or scheduled test is performed on the busied out
packet-control until it is released. A warning alarm (error type 18) is generated on
the busied out packet-control, so that INADS can determine the state of the
object. The release packet-control command reactivates the board and initiates
recovery on all point-to-point signaling links terminated on this packet-control.
Feature Interactions
In a duplicated system, the packet-control busyout of standby process
complex is not allowed.
When the packet-control in the active control complex is busied out, all
connectivity across the Packet Bus is severed. Thus, all ISDN-BRI
point-to-point signaling links that have been established through the active
packet-control are torn down by the busyout packet-control command.
The release packet-control command re-establishes all Packet Bus
connectivity.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
Name of busied out maintenance object: MODEM-PT
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
busyout
packet-
control
location Applies to duplicated
configurations only - a
carrier that contains
packet-control in the
system. Valid locations =
1A or 1B.
Examples
busyout packet-control
1A
busyout packet-control
1B
init
inads
craft
simplex
systems
(optional) =
cabinet 1,
carrier A
duplex
systems =
cabinet 1,
carrier of
choice.
See below

Table of Contents

Related product manuals