test cdr-link
Issue 4 May 2002
A-119 555-233-123
If the standby SPE is not refreshed and the active SPE is hard selected via the
SPE select switches when this command is executed, then the following message
appears:
Active SPE locked via select switches;
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message appears
Standby SPE busy with another task;
for information use “status system 1"
If the standby SPE is not available when this command is executed, then the
following message appears:
Standby SPE not available;
for information use “status system 1"
test cdr-link
Help Messages
If the system technician presses HELP after entering “test cdr-link” the following
message appears:
Enter ’primary’ or ’secondary’
If the system technician presses HELP after entering “test cdr-link primary” or “test
cdr-link secondary” the following message appears:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the link is not administered, the following error message appears:
Link not administered or not enabled
If no tests can be found for the link, the following message appears:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit