Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-226 Issue 4 May 2002
monitor health
Use monitor health to see the current system alarm summary, maintenance busy
summary, user summary, critical system status, and cabinet status that are
updated each minute.
Output
The following example is a display of monitor system health.
Action/
Object Qualifier
Qualifier
Description Logins Default
Feature
Interactions
monitor
health
init
inads
craft
cust
nms
browse
none If standby SPE Emergency
Transfer Select Switches change
and handshakes are down, the
displayed Emerg Trans field is
incorrect until handshake
reintializes.
When the monitor health
command terminates, users are
logged off of the system.
status health
ALARM SUMMARY CABINET STATUS
Major: 0
Minor: 9 Emerg Alarms
Warning: 4 Cab Trans Mj Mn Wn PNC
1 off 0| 7| 0 up
BUSY-OUT SUMMARY 2 off 0| 0| 4 up
Trunks: 0 3 n.a. 0| 2| 0 up
Stations: 0 4 off 0| 0| 0 up/up
Others: 0
PROCESSOR OCCUPANCY STATUS
Static: 3% SM: 6%
CP: 10% Idle: 81%
CRITICAL SYSTEM STATUS
Active SPE: A/auto
Duplicated? SPE:n
SPE Power: commercial
Time Source: external 9:33 TUE JAN 29 1991
# Logins: 2 - Press CANCEL to quit -