test network-control
Issue 4 May 2002
8-463555-233-123
test network-control
This command performs hardware diagnostic tests on a specified network control
circuit pack.
!
WARNING:
Since the clear long options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
network-
control
location
short
long
repeat
number
clear
schedule
Network control board carrier location in a
High or Critical Reliability System (a or b).
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
series of both destructive and nondestructive
diagnostic tests.
Number of times each test in the sequence is
repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence fails.
1
Command is validated and then a scheduling
form displays to schedule execution of the
command. The command is then placed in
the command queue and is executed at the
specified time. The information displayed by
the command is sent to the system printer
instead of the screen.
2
Examples:
test network-control
test network-control a l
test network-control b sh r 2
test network-control b l r 25
test network-control a
test network-control a c
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Cabinet 1,
carrier a,
test
sequence
repeat = 1.
none

Table of Contents