Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-292 Issue 4 May 2002
Other MOs Affected by this Command
NOTE:
Although alarms on some MOs appear as warnings, the alarms should be
investigated with user-related problems.
■ EPN Maintenance Circuit Pack (MAINT)
■ Expansion Interface (EXP-INTF)
■ ISDN-PRI Signaling Group (ISN-SGR)
■ Journal Printer (JNL-PRNT)
■ PMS Link (PMS-LINK)
■ PMS log printer (PMS-LOG)
■ Primary CDR Link (PRI-CDR)
■ Secondary CDR Link (SEC-CDR)
■ SPE Select Switches (SPE-SELEC)
■ Synchronization (SYNC)
■ System Communication Interface (PI-SCI)
■ System Printer (SYS-PRNT)
■ TDM Clock (TDM-CLK)
■ Tone Generator Circuit Pack (TONE-BD)
set signaling-group
This command upgrades secondary D-channel in specified signaling groups to
primary D-channels. Current primary D-channel then revert to secondary
D-channels.
A signaling group is a collection of B-channels that designate single D-channels or
a set of D-channels signals over an ISDN-PRI.
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
set
signaling-group
group
identifier
administered number associated with
each signaling group.
Examples:
set signaling-group 1
set signaling-group 2
init
inads
craft
none none