Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-378 Issue 4 May 2002
status pms-link
This command displays the status of the property management system interface
link. If the link is up, whether or not a data base swap is taking place between the
switch and the property management system (PMS), is displayed. If the link is
down, the number of times the switch has tried to set up the link is displayed.
A PMS is a standalone computer system that can be integrated with the switch to
enhance the service capability for a hotel/motel.
For general information on PMS links, see the description of the ‘‘busyout
pms-link’’.
Output
The following example shows the output from the status pms-link command.
Field descriptions
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
status
pms-link
print Report sent to printer
Examples:
status pms-link
status pms-link print
init
inads
craft
cust
browse
none none
Physical Link
State
Up
, down, or extension not administered; link is
considered administered only if an extension is given in the
System Hospitality form.
Protocol State
up
, down, or blank if not administered.
Number of
Retries
Number of times the switch has tried to set up the link (only
displayed when the link is down; range 1-999)
Maintenance
Busy
yes
or no (technician has or has not busied out the link),
blank if PMS link not administered.
status pms-link
PMS LINK STATUS
Physical Link State: down
Protocol State: down
Number of Retries: 3
Maintenance Busy? no