test processor
Issue 4 May 2002
A-141 555-233-123
test processor
Help Messages
If the system technician presses HELP after entering “test processor” on a simplex
SPE system the following message appears:
Enter [’long’ or ’short’],
[’repeat’(1-100) or ’clear’], [’schedule’]
If the system technician presses HELP after entering “test processor” on a duplex
SPE system the following message appears:
Enter [cabinet(1)];carrier(A-B),
[’long’ or ’short’],
[’repeat’(1-100) or ’clear’], [’schedule’]
Error Messages
For SPE duplex systems, if no carrier is entered on the command line, the
following message appears:
A carrier must be specified for duplex systems
For any system, if the length of the user entered parameter exceeds three (3), the
following message appears:
Entry invalid
On any system, if any cabinet other than “1” or “01” is specified, the following
message appears:
Only cabinet ’1’ may be specified for this command
If a carrier is entered which is not valid for the current system configuration (for
example, anything other than “A” or “B” for SPE duplex and anything other than
the ’a’ carrier for SPE simplex), the following message appears:
Carrier out of range;
Enter ’a’ if SPE simplex, ’a’ or ’b’ if SPE duplex
If the standby SPE was specified, and it does not respond, the following message
appears:
Standby SPE not available;
for information use ’status system’
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
’login id’:’command’ has a command conflict