test pkt
Issue 4 May 2002
8-467555-233-123
test pkt
The test pkt runs a series of tests on the Packet bus of the specified PPN or EPN.
!
WARNING:
Since the clear long options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
Action/Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test pkt
port-network
pn number
short
long
repeat
number
clear
schedule
The Packet bus to be tested: nn (1-3)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
sequence fails.
1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The
command is then placed in the
command queue and is executed at the
specified time. The information
displayed by the command is sent to
the system printer instead of the
screen.
2
Examples:
test pkt port-network 1 l
test pkt port-network 2 sh r 2
test pkt port-network 2 sh schedule
test pkt port-network 1 l r 25
test pkt port-network 2
test pkt port-network 1 c
1 If no alarms are registered against the maintenance object, then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence =
short;
Repeat = 1
none