FL-DATA (Flash Data Consistency)
Issue 4 May 2002
10-827555-233-123
FL-DATA (Flash Data Consistency)
In systems with high or critical reliability, the software and the hard patch update
files are stored in the on-board flash memory in both the Active SPE and Standby
SPE. The translations and announcements are stored in the memory cards in
both the Active SPE and Standby SPE. Flash Data Consistency flags problems
when files become mismatched by monitoring the translations, announcements,
update files, and software vintage number in a High or Critical Reliability PPN
system. If the software vintage numbers on both SPEs are mismatched, a MAJOR
alarm is raised. If the announcement files on both memory cards are mismatched,
a WARNING alarm is raised. For all other problems, a MINOR alarm is raised.
The software vintage can be displayed via the list configuration
software-vintage long command. The Flash Data Consistency Test is run on
system technician command and as part of daily Standby SPE maintenance.
NOTE:
Flash Data Consistency is not applicable to Standard systems.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log) Alarm Level
Initial Command to
Run Full Name of MO
FL-DATA MAJOR test card-mem a|b l Flash Data Consistency
FL-DATA MINOR test card-mem a|b l Flash Data Consistency
FL-DATA WARNING test card-mem a|b l Flash Data Consistency
Table 10-302. Flash Data Consistency Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
0
1
0 Any Any Any test card-mem a/b l
8 or 16 8 or 16 Flash Data Consistency
Test (#421)
WNG OFF test card-mem a/b
1-3,
9-10,
17-18,
32-34,
40-42,
48-50,
Continued on next page