test packet-control
Issue 4 May 2002
8-465555-233-123
test packet-control
This command performs hardware diagnostic tests on the specified packet-control
circuit pack.
Feature Interactions
The reset packet-control test (#586) does not run on the active packet-control.
This test is part of the standby packet-control test sequence, illustrated in the
screen output section below.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
test
packet-
control
location
short
long
repeat
number
clear
schedule
Applies only to duplicated configurations: if simplex,
parameter is not used and thus is not valid; if
duplicated, location represents the carrier in which
the packet-control resides (1A or 1B).
Option for a brief series of nondestructive diagnostic
tests.
Option for a longer, more comprehensive series of
both destructive and nondestructive diagnostic
tests.
How many times each test in the sequence is
repeated (1-100)
This option causes the test sequence (short or long)
to repeat until the alarm (if any) is cleared or a
single test in the sequence fails.
1
Command is validated and then a scheduling form
displays to schedule execution of the command.
The command is then placed in the command
queue and is executed at the specified time. The
information displayed by the command is sent to the
system printer instead of the screen.
2
Examples:
test packet-control
test packet-control A
test packet-control B
test packet-control 1A
test packet-control 1B
test packet-control a short
test packet-control a s repeat 5
test packet-control b s r 5
test packet-control b long clear
test packet-control b l r 25
1 If no alarms are registered against the maintenance object then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
nms
Simplex:
location
optional,
cabinet=1,
carrier A.
Duplex:
cabinet=1,
no default
for the
carrier.
See below

Table of Contents