Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-32 Issue 4 May 2002
change synchronization
Each system contains a hierarchy of sources used for timing synchronization.
DS1 inputs to the external stratum 3 clock affect stratum 3 synchronization
hierarchy. Primary and secondary fields reflect Stratum 4 synchronization. If all
fields are blank, the tone clock board within each PN provides timing for that PN.
Output
The following example shows the output for the change synchronization
command. “4” was entered in the stratum field.
The following output example shows the output for the change synchronization
command. “3” was entered in the stratum field.
Action/Object Qualifier
Qualifier
Description Logins Defaults
Feature
Interactions
change
synchronization
Examples:
change
synchronization
change synch
init
inads
craft
cust
rcust
bcms
none DS1 interface,
BRI trunk, or
UDS1 board
selected as a
primary or
secondary synch
source cannot be
removed on the
DS1 circuit pack
administration
form or the
regular circuit
pack
administration
form.
change synchronization Page 1 of 1
SYNCHRONIZATION PLAN
SYNCHRONIZATION SOURCE (circuit pack location)
Stratum: 4
Primary: _____ Secondary: _____
Location Name Slip Location Name Slip
NOTE: DS1 and BRI trunk source will result in stratum 4, type II synchronization