change synchronization
Issue 4 May 2002
8-33555-233-123
Field descriptions
Stratum Current synchronization stratum (3, 4)
Primary First choice system synchronization source (blank entry = no
synchronization); field valid only if stratum 4 synchronization is
specified.
Secondary Second choice system synchronization source (blank = no
synchronization); valid if stratum 4 synchronization selected
Location Circuit pack location of all administered DS1 circuit packs (port
network, carrier, and board slot)
Name User-defined name for the DS1 circuit pack (blank = no user-defined
name assigned)
Slip If DS1 circuit pack has slip alarm,
y; if not, n.
Port
Network
Display-only field specifying the port network that supplies
synchronization through the tone clock circuit pack (valid for stratum 3
synchronization)
change synchronization Page 1 of 1
SYNCHRONIZATION PLAN
SYNCHRONIZATION SOURCE (DS1 circuit pack location)
Stratum: 3
Port Network: 1