Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-52 Issue 4 May 2002
disable synchronization-switch
This command stops the automatic clock switching capability of the maintenance
subsystem. The clock refers to the oscillator on a tone/ clock or DS1 interface.
The synchronization subsystem (TDM bus clock, DS1 trunk board, and
maintenance and administration software) provides error-free digital
communication between the switch and other PBXs, COs, or customer
equipment.
disable test-number
This command prohibits selected maintenance tests from running. To run a
disabled test number, enter the enable test-number command.
Action/Object Qualifier
Qualifier
Description Logins Defaults
Feature
Interactions
disable synchronization-
switch
init
inads
craft
none none
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
disable
test-
number
number
print
schedule
Maintenance test number
Report sent to printer
Command is validated and then
a scheduling form displays to
schedule execution of the
command. The command is
then placed in the command
queue and is executed at the
specified time. The information
displayed by the command is
sent to the system printer
instead of the screen.
1
Examples:
disable test-number 710
disable test-number 710 print
disable test-number 510
schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
none none