EasyManua.ls Logo

Avaya Definity SI - Busyout Data-Module

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-6 Issue 4 May 2002
busyout data-module
This command puts the specified data module in a maintenance busy state, even
uninstalled data modules. No periodic or scheduled tests is performed on the
busied out data module or data channel until it is released and no call processing
can be executed on the data modules or over the data channels. Warning alarms
are generated (error type 18) on each maintenance object busied out, so that
INADS can access the state of the objects. The release data module command
returns the specified data module (or data channel) to operation.
On duplicated systems, a busyout of a Network Control Data Channel
(DATA-CHL) or a Processor Interface Port Data Channels (PI-PT) are preserved
across SPE interchanges. The data channel extension must be released before
the data channel can be brought back into service.
Output
The following example shows the output from busyout data-module 300.
Action/Object Qualifier
Qualifier
Description Logins Defaults
Feature
Interactions
busyout
data-module
extension Extension number
(per dial-plan)
Example:
busyout
data-module 31300
init
inads
craft
nms
None None
busyout data-module 300 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1103 DIG-LINE 300 PASS
Command successfully completed