test ds1-loop
Issue 4 May 2002
A-121 555-233-123
If the extension is not administered, the following message appears:
Extension not assigned
If the object associated with the specified extension is not a data module or a data
channel, the following message appears:
Extension exists but assigned to a different object
If the EPN that contains the data module port is not accessible, the following
message appears:
EPN is not available
If the board that contains the data port is not configured in the system, the
following message appears:
Board not assigned
If no tests can be found for the current MO, the following message appears:
No tests for this MO
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
login id:command has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
test ds1-loop
Help Messages
If the system technician presses HELP after entering test ds1-loop the following
message appears:
Enter DS1 board location,
[cpe-loopback-jack-test-begin [number-of-bits bit-pattern] or
far-csu-loopback-test-begin or one-way-span-test-begin or
end-loopback/span-test or inject-single-bit-error or
ds1/csu-loopback-tests]

Table of Contents