Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-122 Issue 4 May 2002
Error Messages
If the format for the board location is incorrect, the following error message
appears:
Port/Board invalid
If the EPN in which the specified board resides is not available, the following
message appears:
EPN is not available
If the specified board is not inserted in the system, the following message
appears:
Board not inserted
If the command entered is in conflict with another currently executing command,
then a message appears showing the login id of the conflicting user and the
conflicting command. The message is as follows:
login id:command has a command conflict
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
If the test ds1-loop command is executed and the Version field on the
system-parameters customer-options form is not V5 or later, then the following
message appears:
G3 Version must be V5 or later
If the test ds1-loop command is executed on a circuit pack other than TN464F or
TN767E or later DS1 board, then the following message appears:
Command valid for TN464F or TN767E or
later release DS1 circuit packs
If the inject-single-bit-error parameter is selected, but no CPE Loopback Jack,
far-end CSU, or one-way span test is active on the DS1 circuit pack, then the
following message appears:
Parameter valid only if a loopback/span test is active on the DS1

Table of Contents