EasyManua.ls Logo

Avaya Definity SI - Test Cdr-Link

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
test cdr-link
Issue 4 May 2002
8-425555-233-123
Field descriptions
test cdr-link
The test cdr-link command validates that a call detail recording link has been
administered and established. The test defaults to short.
Parameters
Port
Port address (cabinet-carrier-slot-circuit): cabinet 1, carrier is A
(control carrier A in a simplex system) and either A or B (control
carriers A and B in a duplex system). The slot and circuit fields in
the port address for the CAP-MEM, and CARD-MEM maintenance
objects are always blank. The port address for maintenance object
FL-DATA is blank.
Maintenance
Name
The name of maintenance object being tested:
CARD-MEM for the memory card
CAP-MEM for memory card capacity
FL-DATA for the data consistency stored in memory cards
(duplicated switch)
Test No
The test being executed
Result
Test result: Pass, Fail, or Abort
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of the codes by test number for each MO.
test cdr-link primary | secondary
[short | long] [repeat number | clear] [schedule]
[primary |
secondary]
A system may have up to two CDR links: a primary that is normally
used and a secondary that serves as a backup in case the primary
fails. This qualifier specifies which link to test. Primary is the default.

Table of Contents