busyout trunk
Issue 4 May 2002
8-23555-233-123
Field descriptions
busyout trunk
This command places the specified installed or uninstalled trunk group or trunk
group member in a maintenance busy state. No periodic or scheduled tests are
performed on the busied out trunk groups or trunk group members until they are
released. When the object is maintenance busy it is deactivated (no call
processing activity may include the busied object). A single group member can be
busied out by specifying the group and member number. All members in a trunk
group can be busied out by specifying the trunk group number. Warning alarms
(error type 18) are generated on each busied out maintenance object, so that
INADS can access the state of the objects. The release trunk command
reactivates the specified trunk group or group member.
NOTE:
If the user enters busyout trunk <group number>/, the lowest port-location
in the group is busied out. This is NOT recommended.
Port
Tone/clock board address (cabinet-carrier)
Maintenance Name
Circuit pack name: TONE-PT, TDM-CLK, TONE-BD
Alt. name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
Action/
Object Qualifier Qualifier Description Logins Defaults
Feature
Interactions
busyout
trunk
group
member
Trunk group number (1–99)
Number of a trunk within a
trunk group (1 – 99)
Examples:
busyout trunk 78
busyout trunk 78/1
init
inads
craft
none none