Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-24 Issue 4 May 2002
Output
The following example is a display of the busyout trunk command.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
Type of busied out maintenance object.
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
See the detailed list of codes by test number for each MO.
busyout trunk 78/1 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1505 CO-TRK 78/01 PASS
Command successfully completed